- 1 LED tube
- 1 dummy starter
- 1 operating instructions
| Indice de rendu des couleurs | 80 |
| Température de couleur | Blanc neutre |
| Alimentation | 230 V |
| Angle moyen du faisceau | 220 ° |
| Angle nominal du faisceau | 220 ° |
| Classe d'efficacité énergétique (A à G) | F |
| Consommation d'énergie pondérée | 9 kWh/1000h |
| Consommation nominale | 9 W |
| Facteur d'éfficacité | 0,9 |
| Facteur de maintien du flux lumineux à 6000 h | 0,8 |
| Flux lumineux nominal | 900 lm |
| Fréquence secteur | 50 Hz |
| Rég. EAR N° | DE 38720470 |
| Rendement lumière nominal | 900 lm |
| Stabilité de la couleur | 6 |
| Taux de défaillance prématurée | 5 % |
| Temps de chauffe pour atteindre 95% de la luminosité | 1 s |
| Compatible avec les variateurs | Non |
| Couleur lumière / couleur température | Neutral White - 4000 K |
| Douille | G 13 |
| Durée de vie | 30000 h |
| Equivalente à une ampoule à incandescence de | 18 W |
| Facteur de durée de vie (6000 h) | 0,9 |
| Nombre de cycles d'allumage avant défaillance prématurée | 30000 |
| Position de fonctionnement | 360 ° |
| Rendement lumineux | 100 lm/W |
| Structure | T8 ø 26 mm en forme de tube |
| Température de couleur | 4000 K |
| Température optimale | 25 °C |
| Temps d'allumage | 0,5 s |
| Type de LED | SMD |
| Valeur RA | 80 |
| Diamètre | 29,5 mm |
| Hauteur | 600 mm |
| Poids Net | 122 g |
| Consommation moyenne de l'ampoule | 9 W |
| Durée de vie | 30000 h |
| Facteur de conservation du flux lumineux (LLMF) | 70 |
| Voltage | 50 mA |
| Permet de remplacer une ampoule de type | Tube fluorescent |
Only for private use and not for long-term commercial use
Only for use in individual switching (lights have their own starter for each fluorescent tube)
Not suitable for electronic ballasts (lights without starters)
CLB = Conventional Loss Ballast, the most widespread system
LLB = Low Loss Ballast
EB = Electronic Ballast
Any changes to the wiring should only be carried out by qualified electricians. Incorrect installation could result in injury or damage to property.
Before carrying out any conversion work, ensure that there is no voltage.
Any defects due to incorrect installation are not covered by the warranty.
In addition to the power consumption of the LED tubes, CLBs that have not been disconnected/bypassed in particular have a high and unnecessary power loss and can cause high voltage peaks. Voltage peaks reduce the service life of the tubes. The disconnection/bypass must only be carried out by a qualified electrician.
Power loss in LLBs is considerably lower and so disconnection/bypass is not so important.
If a light that has been converted to LED tubes is fitted with fluorescent tubes once again, a fluorescent tube starter will need to be refitted. Every light that has been converted to LED tubes should feature a warning notice next to the starter.
The overall efficiency and light distribution is determined not just by the characteristics of the LED tubes, but also by the construction and characteristics of the lights.