What's in the Box

- 1 LED tube
- 1 dummy starter
- 1 operating instructions

Technical Specs

Colour Reproduction Index RA (min.) 80
Light Colour Neutral White
Colour Consistency 6
EAR Reg.No. DE 38720470
Electrical Efficiency Factor of the Bulb (min.) 0.9
Energy Efficiency Class A to G F
Lamp Lumen Maintenance Factor at 6000h 0.8
Mains Frequency 50 Hz
Nominal Beam Angle 220 °
Nominal Light Output 900 lm
Nominal Power Consumption 9 W
Operating Voltage 230 V
Premature Failure Rate 5 %
Rated Beam Angle 220 °
Rated Light Output 900 lm
Start-Up Time Until 95% of Full Light Output Has Been Reached (max.) 1 s
Weighted Energy Consumption 9 kWh/1000h
Can be Dimmed No
Colour Temperature 4000 K
Design T8 ø 26 mm rod-shaped
Lamp socket G 13
Lamp Survival Factor at 6000h (min.) 0.9
LED Type SMD
Light color / color temperature Neutral White - 4000 K
Light efficiency 100 lm/W
Nominal Service Life 30000 h
Number of Switching Cycles until Premature Failure (min.) 30000
Operating Position 360 °
Optimal Ambient Temperature 25 °C
Power Consumption of an Equivalent Incandescent Lamp 18 W
RA-Value 80
Starting Time (max.) 0.5 s
Diameter 29.5 mm
Height 600 mm
Net Weight 122 g
Lamp Current 50 mA
Lamp Lumen Factor at End of Nominal Service Life (min.) 70
Rated Power Consumption 9 W
Rated Service Life 30000 h
Bulb Serves as Replacement for Standard Bulbs of This Size Fluorescent Tube

Note for Consumers

Only for private use and not for long-term commercial use
Only for use in individual switching (lights have their own starter for each fluorescent tube)
Not suitable for electronic ballasts (lights without starters)

CLB = Conventional Loss Ballast, the most widespread system
LLB = Low Loss Ballast
EB = Electronic Ballast

Any changes to the wiring should only be carried out by qualified electricians. Incorrect installation could result in injury or damage to property.
Before carrying out any conversion work, ensure that there is no voltage.
Any defects due to incorrect installation are not covered by the warranty.
In addition to the power consumption of the LED tubes, CLBs that have not been disconnected/bypassed in particular have a high and unnecessary power loss and can cause high voltage peaks. Voltage peaks reduce the service life of the tubes. The disconnection/bypass must only be carried out by a qualified electrician.
Power loss in LLBs is considerably lower and so disconnection/bypass is not so important.

If a light that has been converted to LED tubes is fitted with fluorescent tubes once again, a fluorescent tube starter will need to be refitted. Every light that has been converted to LED tubes should feature a warning notice next to the starter.

The overall efficiency and light distribution is determined not just by the characteristics of the LED tubes, but also by the construction and characteristics of the lights.