- 1 LED filament
Indice de rendu des couleurs | 80 |
Température de couleur | Blanc chaud |
On-mode power (Pon): | 11 W |
Beam angle | 300 ° |
Colour-tuneable light source | No |
Energy Efficiency Class A to G | D |
Energy consumption in on-mode | 11 kWh/1000h |
L70B50 lifetime for LED and OLED light sources | 15000 h |
Stroboscopic effect for LED and OLED MLS | 0.4 |
Shift factor for Pon (min.) | 0.91 |
Survival factor (for LED and OLED) | 0.9 |
Lumen maintenance factor (LED/OLED) | 93,11 % |
Flicker for LED and OLED MLS | 1 ≤ |
Useful luminous flux (Φ360) | 1521 lm |
Frequency | 50 Hz |
R9 colour rendering index value | 17 |
EAR Reg.No. | DE 38720470 |
Connected light source (CLS) | No |
Light source | Non-directiona |
Colour Consistency | 4 ≤ |
Lighting technology used | LED Lamp |
Input Voltage | 220-240 V |
IP protection class | IP20 (Dry Rooms) |
Can be Dimmed | Yes |
Lamp socket | E 27 |
Power Consumption of an Equivalent Incandescent Lamp | 100 W |
Special Feature | LED-Filament |
Operating Position | 360 ° |
Design / Diameter / Height | Light Bulb / 60 mm / 105 mm |
Colour Temperature | 2700 K |
Optimal Ambient Temperature | 25 °C |
Dimming | Dimmer |
Net Weight | 36 g |
Lamp Current | 52 mA |
Suitable for Accent Lighting | No - Beam Angle between 120° and 360° (Φuse) |
The LED light is designed for operation in open luminaires: the heat generated by the light during operation can therefore be emitted into the surroundings. The service life prognosis is based on this mode of operation. The service life is reduced by insufficient cooling when used in enclosed luminaires. Only use in lights intended for its use. Allow the light to cool down completely before changing it and switch off the power supply voltage. Damaged lights should be replaced immediately. No liability shall be assumed for damage caused by incorrect use.
Some dimmers can impair the function of the light (flickering, noise).
Mixed operation, i.e. the simultaneous operation of LED bulbs and standard incandescent bulbs or LED bulbs of different types on one dimmer cable, is not possible. If noises are heard with dimmers that were not noticed with incandescent bulbs: the dimmer is not suitable for LED bulbs.
Cable dimmers (dimmer integrated into the power cable) require a separate on/off switch since they may not be able to regulate right down to 0.
Note the dimmer's minimum load, otherwise it may not switch on or it may control the light incorrectly. Simple dimmers usually work from 60W to 400W.
With integrated dimmers that have a basic brightness setting, this must be set high enough otherwise the LED bulb may not switch on.
Dim slowly and evenly. Do not dim quickly or with jerky movements.
Only incandescent bulb dimmers are permitted - not dimmers for transformers, etc.
Touch dimmers are usually not suitable. Incorrect dimmers can permanently damage lighting.