 - 1 LED tube
- 1 dummy starter
- 1 operating instructions
| Farbwiedergabeindex RA (min.) | 80 | 
| Lichtfarbe | Neutralweiß | 
| Anlaufzeit bis zur Erreichung von 95% des vollen Lichtstroms | 1 s | 
| Bemessungs-Halbwertswinkel | 220 ° | 
| Bemessungs-Nutzlichtstrom | 900 lm | 
| Betriebsspannung | 230 V | 
| EAR Reg.Nr. | DE 38720470 | 
| Elektrischer Leistungsfaktor der Lampe (min.) | 0,9 | 
| Energie Effizienz Label (A bis G) | F | 
| Farbkonsistenz | 6 | 
| Frühausfallrate | 5 % | 
| Gewichteter Energieverbrauch | 9 kWh/1000h | 
| Lichtstromerhalt bei 6000h | 0,8 | 
| Nennleistungsaufnahme | 9 W | 
| Netzfrequenz | 50 Hz | 
| Nominaler Halbwertswinkel | 220 ° | 
| Nominaler Nutzlichtstrom | 900 lm | 
| Bauform | T8 ø 26 mm stabförmig | 
| Brennlage | 360 ° | 
| Dimmbar | Nein | 
| Farbtemperatur | 4000 K | 
| Lampenlebensdauerfaktor bei 6000h (min.) | 0,9 | 
| Lampen Sockel | G 13 | 
| LED Typ | SMD | 
| Leistungsaufnahme einer äquivalenten Glühlampe | 18 W | 
| Lichtausbeute | 100 lm/W | 
| Lichtfarbe/Farbtemperatur | Neutralweiß - 4000 K | 
| Nennlebensdauer | 30000 h | 
| Optimale Umgebungstemperatur | 25 °C | 
| RA-Wert | 80 | 
| Zahl der Schaltzyklen bis zum vorzeitigen Ausfall (min.) | 30000 | 
| Zündzeit (max.) | 0,5 s | 
| Durchmesser | 29,5 mm | 
| Höhe | 600 mm | 
| Nettogewicht | 122 g | 
| Bemessungs-Lebensdauer | 30000 h | 
| Bemessungs-Leistungsaufnahme | 9 W | 
| Lampenlichtstromfaktor am Ende der Nennlebensdauer (min.) | 70 | 
| Lampenstrom | 50 mA | 
| Lampe ist Ersatz für Standardlampen der Größe | Leuchtstoffröhre | 
 Only for private use and not for long-term commercial use
Only for use in individual switching (lights have their own starter for each fluorescent tube)
Not suitable for electronic ballasts (lights without starters)
CLB = Conventional Loss Ballast, the most widespread system
LLB = Low Loss Ballast 
EB = Electronic Ballast
Any changes to the wiring should only be carried out by qualified electricians. Incorrect installation could result in injury or damage to property.
Before carrying out any conversion work, ensure that there is no voltage. 
Any defects due to incorrect installation are not covered by the warranty. 
In addition to the power consumption of the LED tubes, CLBs that have not been disconnected/bypassed in particular have a high and unnecessary power loss and can cause high voltage peaks. Voltage peaks reduce the service life of the tubes. The disconnection/bypass must only be carried out by a qualified electrician. 
Power loss in LLBs is considerably lower and so disconnection/bypass is not so important.
If a light that has been converted to LED tubes is fitted with fluorescent tubes once again, a fluorescent tube starter will need to be refitted. Every light that has been converted to LED tubes should feature a warning notice next to the starter.
The overall efficiency and light distribution is determined not just by the characteristics of the LED tubes, but also by the construction and characteristics of the lights.